Add to Cart
1. S11 11KV 33KV 20A -5000A 3 Phas H.V. Oil Type Power Transformer
1.1. Magnetic Core
The three-limb iron core is made of oblique cut Grain-oriented, seven-step silicon steel lamination insulated on both sides, guaranteeing low losses and low noise. These values are even improved by laser treatment. It is protected on the surface with a flash-proof varnish in order to prevent the sheet from corrosion and to reduce the noise.
1.2. The winding
The winding as the centerpiece of the transformer must be especially protected – both against high electrical stress due to external overvoltage and against mechanical overloads by short circuits. Varelen transformers are systematically designed to meet these requirements. The windings are made of copper or aluminum. Low-voltage windings are made of strip or flat wire, and the high voltage windings are manufactured from round or profile wire. (“diamond-dotted paper”) bonds the winding into a compact block while drying and increases the short-circuit capacity additionally.
1.3. The Tank Whether during transport or operation –the tank must be absolutely tight under mechanical stress. Preconditions to achieve this are constructional experience, the most modern calculation methods, and high-quality welding work. Special attention is paid to corrosion protection. Pretreatment of the surface is processed by phosphating pickling, contributes to corrosion protection, just like multi-coating with preset drying times for each layer. On request, hot-dip galvanization provides for even better protection.
2. Data
Standard | GB1094,GB 6450-86,GB/T10228-1997,meet with DIN42523,IEC726 |
Capacity range | 30-16000KVA |
Voltage class | 10KV-35KV |
Volt-regulation means | no-excitation volt-ragulation or on-load volt-regulation. |
Tapping range | +/-5%,+/-2*2.5%.+/-4*2.5% |
Frequency | 50 or 60Hz |
Number of phase | three or single phase |
Coupling group tab | Yyn0,Dyn 11 or others |
Highest temperature-rise | 100K. |
Cooling method | self-cooling(AN) of forced air cooling(AF) |
Protection Class | IP00,IP20,1P23 |
Insulation class | F |
3. Product Characteristics:
1. safe, fire-retardant, fireproof and pollution-free.
2. It can be directly installed at the load center, is free of maintenance and easy and convenient to install, and has low comprehensive running cost.
3. With high moisture resistance, it runs normally at the moisture of 100% and can be put into operation without being dried after outage, with low loss and local discharge capacity.
4. It has small noise, strong short circuit resistance and excellent environmental performance, and can run under severe environmental condition.
4. Photo
5. Factory
6. Delivery