Xi'an Xigao Electricenergy Group Co., Ltd.

Xi'an Xigao Electricenergy Group Co., Ltd.

Manufacturer from China
Verified Supplier
5 Years
Home / Products / Vacuum Circuit Breaker /

Three Phase 40.5Kv Outdoor VCB Breaker Power Distribution System

Contact Now
Xi'an Xigao Electricenergy Group Co., Ltd.
Visit Website
Province/State:shanxi
Country/Region:china
Contact Person:Emma
Contact Now

Three Phase 40.5Kv Outdoor VCB Breaker Power Distribution System

Ask Latest Price
Video Channel
Brand Name :XG
Model Number :ZN23
Certification :ISO CCC
Place of Origin :XIAN, China
MOQ :1set
Price :Negitionable
Payment Terms :L/C, T/T, D/A, D/P, Western Union, MoneyGram
Supply Ability :2000 SET
Delivery Time :7-15 DAYS
Packaging Details :WOODEN CASE
Name :Outdoor VCB Breaker
Application :Power Distribution System
Warranty :12 months
OEM :Yes
Voltage :40.5Kv
Operation type :electric or manual
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Three Phase 40.5Kv Outdoor VCB Breaker Power Distribution System

1. Outdoor VCB Breaker

ZN23-40.5 Acb Circuit Breaker is 40.5 KV rated voltage, three-phase ac 50 hz indoor high voltage electrical equipment, applicable to substations, industry and mining, urban and rural electric power networks, especially for occasions with frequent operation and automatic power distribution network.


2. Parameter of Outdoor VCB Breaker

NO Item Units Technical parameters
1 Rated voltage kV 40.5
2 Thunder impulse withstand voltage(peak value) kV 185
3 lmin industrial frequency withstand voltage kV 95
4 Rated frequency Hz 50
5 Rated current A 1250,1600,2000
6 Rated short-circuit break current kA 25 31.5
7 Rated peak value withstand current kA 25 31.5
8 Rated peak value withstand current KA 63 80
9 Rated short-circuit duration time s 4
10 Rated short circuit breaking time ms
11 Rated short circuit closing current kA 80
12 Rated operation order 0-0.3s-C0-180s-C0
13 Time of closing brake ms 50~85
14 Time of breaking brake ms 40~85
15 Rated short-circuit current break and close times Times 20
16 Mechanical life-span Times 10000
17 Rated dropout current of condenser bank A 630
18 Rated power of energy-storage electric machine W 275
19 Rated volt of energy-storage motor V 25 ± 2
20 Storage time S ≤15
21 Closing and opening solenoid rated voltage V ≈220,110
22 Loss of pressure tripping device rated voltage V ≈220,110
23 Over current tripping device rated current A 5
24 Auxiliary switch rated voltage current A DC10


3. Working application
Amplitude: earthquake intensity does not exceed 8 °,
Air relative humidity on average less than 95%, on average less than 90%
An ambient air temperature: to +40 °C, the lower limit of -150°C,
Altitude:. ≤ 1000m (For higher altitudes, the rated insulation board level relative increase)
No risk of fire, explosion, serious pollution, chemical corrosion and severe vibration.

4. Technical drawings


5. Factory
Three Phase 40.5Kv Outdoor VCB Breaker Power Distribution System

Inquiry Cart 0